上海玉研科学仪器有限公司
高级会员第2年 参观人数:221812
  • 参考报价:电议
    型号:
    产地:美国
    在线咨询
  • 详细介绍:


    电生理工作站是一款多功能细胞外记录终端。以精致和实用性为设计理念,为研究人员提供了一个强大的电子数据记录工具。配合控制软件neuro-Guide使用,ARIS可以为您提供了体内电生理学***的工作站。将电极连接到系统上即可开始您的电生理学实验!

    电生理工作站ARIS具备两个独立的操作模式:电脑模式和手动模式。包括下列硬件单元:放大器、放大器、过滤器、刺激发生器、阻抗测量、数据采集模块。

    电生理工作站ARIS的主要特征:

    4通道记录系统

    集成探头

    Spikes,局部场电位(LFP)

    微硬盘

    数据采集

    Spike Sorting

    图谱集成

    ARIS – Electrophysiology Workstation

    ARISis a multifunctional hardware solution for extracellular recording. It was designed with compactness and utility in mind to offer the researchers a powerful electronic tool.

    ARISoffers a state-of-the-art workstation for in-vivo electrophysiology.

    All in one

    • Amplification, conditioning and acquisition of neuronal signals

    • Programmable current stimulus generator

    • Impedance measurement module

    ARISperfectly integrates in a computerized laboratory setting, and can also be used only as a companion tool in a hardware-exclusive recording or stimulation arrangement. Accordingly, it offers two independent operation modes: PC-Control and Manual.

    ARISincorporates even the preamplifier module and connects directly to a laptop or desktop computer.

    Computer controlled electrophysiology research

    This equipment was designed especially for optimal amplification and acquisition of extracellular neuronal signals: single-unit potentials (2 channels) and local field potentials (2 channels). The integrated data card ensures full computer control: channel selection, switching of operation modes (recording, stimulation, impedance), programmable generation of stimulus waveforms of amplitudes up to 1mA @ 250V.

    Clean signal

    The differential input recording channels were designed with care to guarantee maximal immunity to environmental noise. The steep response of the 4th order low-pass and high-pass filters were optimally pre-tuned to ensure a virtually hands-free operation.

    Direct impedance test

    Measurement of microelectrode impedances up to 2MW is realized on-the-fly based on the voltage feedback of the 1nA sinusoidal signal sent to the preparation.

    Computer controlled stimulation current

    The stimulation current is precisely generated by the data card with no additional processing burden on the connected computer. Repetitive current pulse trains or lesioning/marking constant current are supported.

    No cable reconnection

    ARISis capable of no-electrode-touch switching of operation modes: recording, stimulation, impedance testing. That is, the same preparation cable remains in place during the entire experiment.

    请关注玉研仪器的更多相关产品。