上海迈力特环保科技有限公司
高级会员第5年 参观人数:78829
  • 参考报价:电议
    型号:
    产地:
    在线咨询
  • 详细介绍:


    Dust measuring device PFM 02 V
    Application
    The dust concentration measuring device PFM 02 V is used for the continuous measurement of dust contents, especially for the emission measurement according to TI air, 13th, 17th and 27th BImSchV as well as for the dust concentration measurement in process monitorings. Parallel to the dust measurement flow and temperature of the smoke gas are registered (in combination e.g. with FMD 02).

    Technical data


    Control unit: complete electronic in probe head (no separate control unit required), IP 65
    Probe: stainless-steel probe rod (turnable and exchangeable) at the probe head, probe length 300 mm (adjustments possible), IP 65
    Measuring principle: dust: measurement with 1 triboelectric sensor
    Measuring ranges: 0 ... 100 % respectively 0 ... 10 (1.000) mg/m³
    Calibration: by gravimetric reference measurements
    Display: graphic display with online line diagram
    Media temperature: max. 280 °C (higher temperatures on request)
    Ambient temperature: -20 ... +50 °C
    Dew point difference: min. +5 K
    Flow velocity: from appr. 3 m/s
    Analogue signals: 2 x 4 ... 20 mA, galvanically isolated
    Digital signals: 3 potential-free contacts (failure/maint, limit value 1 and 2/maint. request)
    Power supply: 110 VAC, 230 VAC or 24 VDC
    TÜV-approval: TI air, 13th , 17th and 27th BImSchV (in combination with the velocity measurement)