14 年

白金会员

已认证

弹性蛋白聚合物(ELP)凝聚层分析的新型高通量方法

New High-Throughput Method for Elastin-like Polymer (ELP) Coacervate Analysis

弹性蛋白聚合物(ELP)凝聚层分析的新型高通量方法

Posted by Michelle Devoe

Michelle Devoe发表

December 2018 — A recent study by researchers from the University of New England and University of New Hampshire has demonstrated that flow imaging microscopy is an accurate, more efficient, and more informative method of elastin-like polymer (ELP) coacervate analysis than standard methods. ELP coacervates are a class of molecules with promising applications in drug delivery vehicles, tissue engineering, environmental remediation, and more. ELP coacervate architecture is stimuli-responsive and highly tunable, making them ideal for the above-mentioned applications.  

2018年12月 - 新英格兰大学和新罕布什尔大学的研究人员最近的一项研究表明,与标准方法相比,流动成像显微镜是一种准确,更有效,信息更丰富的弹性蛋白样聚合物(ELP)凝聚分析方法。 ELP凝聚层在作为药物递送的载体,组织工程,环境修复等方面具有广阔的应用前景。 ELP凝聚层结构具有刺激响应性和高度可调性,使其成为上述应用的理想选择。

                                       

     


ELP coacervates imaged by the FlowCam. Size and circularity, two of the 40+ properties that can be measured by the FlowCam, is used to sort coacervates. Image from Marvin et al. (2018). 

ELP凝聚了由FlowCam成像的图像。 尺寸和圆度是FlowCam可以测量的40多个属性中的两个,用于对凝聚层进行分类。 图片来自Marvin等。(2018)。

Standard methods for ELP coacervate analysis are indirect and cumbersome. Data from Visible-UV spectrophotometer turbidity measurements and dynamic light scattering (DLS) size measurements are superimposed to evaluate the formation of micron-scale aggregates, and particle geometry is constructed indirectly from diffusion data. Imaging analysis methods such as optical, electron, and scanning probe microscopy are useful methods to acquire size and shape data, however it is time-consuming and laborious to acquire a large enough sample size to get statistically significant data. 

ELP凝聚层分析的标准方法是间接和麻烦的。 来自可见 - 紫外分光光度计浊度测量和动态光散射(DLS)尺寸测量的数据被叠加以评估微米级聚集体的形成,并且颗粒几何形状间接地由扩散数据构建。 诸如光学,电子和扫描探针显微镜之类的成像分析方法是获取尺寸和形状数据的有用方法,然而获得足够大的样本大小以获得统计上有效的数据是耗时且费力的。

In this study by the University of New England and University of New Hampshire, the size, morphology, and behavior of ELP coacervates subjected to various solvent conditions were measured and observed using the FlowCam particle analyzer. Results were validated by comparison with DLS and atomic force microscopy analyses. Flow imaging microscopy was demonstrated to be a successful method for ELP coacervate analysis. Additionally, flow imaging microscopy reported additional findings that were not measured using the DLS, microscopy, or Visible-UV spectrophotometry.

在新英格兰大学和新罕布什尔大学的这项研究中,使用FlowCam颗粒分析仪测量和观察经受各种溶剂条件的ELP凝聚层的尺寸,形态和行为。 通过与DLS和原子力显微镜分析的比较验证结果。 流动成像显微镜被证明是ELP凝聚层分析的成功方法。 此外,流动成像显微镜提供了DLS,显微镜或可见紫外分光光度法不能获得的结果。

 

 

 

麦奇克/Microtrac  2019-09-25  |  阅读:3109
最新文章
更多  
推荐产品 供应产品

分类

虚拟号将在 秒后失效

立即拨打

为了保证隐私安全,平台已启用虚拟电话,请放心拨打
(暂不支持短信)

×
是否已沟通完成
您还可以选择留下联系电话,等待商家与您联系

需求描述

单位名称

联系人

联系电话

已与商家取得联系
同意发送给商家
留言咨询

留言类型

需求简述

联系信息

联系人

单位名称

电子邮箱

手机号

图形验证码

点击提交代表您同意《用户服务协议》《隐私协议》